• SMK 63A SINGLE POLE AC BREAKER 230/400V

    A range of 10x38mm fuse links specifically designed for protecting photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted photovoltaic string arrays
    (reverse current, multi-array fault)

    Structural Characteristics
    □ According to IEC60269-1
    □ Rated current: 1-32A
    □ Rated voltage: DC 1000V
    □ Rated breaking capacity:DC 33kA
    □ Operating class gPV for Solar protection

    Specification
    Pole 1P
    Rated Voltage Ue (V DC) 1000
    Rated Current In (A) 1, 2, 3, 4, 5, 6, 8, 10, 12,15, 20, 25, 32
    Biggest Block Ability(KA) 33
    The Most High Power Consumption(W) 3.5

    1,000.001,500.00
  • SMK 63A DOUBLE POLE AC BREAKER 230/400V

    FPV-63 DC MCB supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protection is already provided or not required. Devices are designed for direct current (DC) control circuit applications.

    Specifications

    FPV-63 Series Circuit Breaker FPV-63
    Frame Degree Rated Current (A) 63
    Pole 2P
    Rated Operating Voltage (V DC) DC12V -DC1200V Rated Current In (A) 1-63A
    Rated Insulation Voltage Ui (V DC) 1200VDC Rated Impact Voltage Uimp (kV) 4
    Ultimate Breaking Capacity Icu (kA) 6
    Run Breaking Capacity LCS (%lcu) 75% Curve Type C
    Trip Type Thermal-magnetic

    1,500.002,000.00
  • 40A 2-POLE CHANGE OVER BREAKER SWITCH

    A range of 10x38mm fuse links specifically designed for protecting photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted photovoltaic string arrays
    (reverse current, multi-array fault)

    Structural Characteristics
    □ According to IEC60269-1
    □ Rated current: 1-32A
    □ Rated voltage: DC 1000V
    □ Rated breaking capacity:DC 33kA
    □ Operating class gPV for Solar protection

    Specification
    Pole 1P
    Rated Voltage Ue (V DC) 1000
    Rated Current In (A) 1, 2, 3, 4, 5, 6, 8, 10, 12,15, 20, 25, 32
    Biggest Block Ability(KA) 33
    The Most High Power Consumption(W) 3.5

    4,500.006,000.00
  • 63A 2-POLE CHANGE OVER BREAKER SWITCH

    A range of 10x38mm fuse links specifically designed for protecting photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted photovoltaic string arrays
    (reverse current, multi-array fault)

    Structural Characteristics
    □ According to IEC60269-1
    □ Rated current: 1-32A
    □ Rated voltage: DC 1000V
    □ Rated breaking capacity:DC 33kA
    □ Operating class gPV for Solar protection

    Specification
    Pole 1P
    Rated Voltage Ue (V DC) 1000
    Rated Current In (A) 1, 2, 3, 4, 5, 6, 8, 10, 12,15, 20, 25, 32
    Biggest Block Ability(KA) 33
    The Most High Power Consumption(W) 3.5

    5,000.006,600.00
  • SMK 500V DC DOUBLE POLE BREAKER

    FPV-63 DC MCB supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protection is already provided or not required. Devices are designed for direct current (DC) control circuit applications.

    Specifications

    FPV-63 Series Circuit Breaker FPV-63
    Frame Degree Rated Current (A) 63
    Pole 2P
    Rated Operating Voltage (V DC) DC12V -DC1200V Rated Current In (A) 1-63A
    Rated Insulation Voltage Ui (V DC) 1200VDC Rated Impact Voltage Uimp (kV) 4
    Ultimate Breaking Capacity Icu (kA) 6
    Run Breaking Capacity LCS (%lcu) 75% Curve Type C
    Trip Type Thermal-magnetic

    8,500.009,500.00

    SMK 500V DC DOUBLE POLE BREAKER

    8,500.009,500.00
  • SMK 4kva 800V 2 pole DC surge protective device

    A surge protector contains metal oxide varistor, or MOV, which diverts any extra voltage to ensure devices receive a consistent power level. The MOV works like a pressure-sensitive valve. When the MOV detects high voltage levels, it reduces resistance. If voltage levels are too low, it increases resistance

    10,000.0012,000.00

Main Menu